■Features
●PID control of IR heater surface temperature 2pcs/channel
●PID control for each hot air zone
●Air supply, exhaust is control per zone
●High safety with overheating prevention, burnout alarm etc.
●Teflon coating conductive glass cloth mesh conveyor belt used
●Free unit combination to fulfill your needs
●Stainless made gas connecting unit
■Specification
| Conveyor width | 700mm |
|---|---|
| Entrance | 1500mm |
| Heating zone | 2000mm/zone |
| Exit (cooling) | 1500mm room temperature with cooling fan within 2000mm zone |
| Pass line | 850mm |
| lRheater | 1.1kw×8pcs/zone |
| Hot wind heater | 9kw/zone |
| Circulation blower | blower per zone |
| Exhust | Exhaust blower with damper per zone, 13㎥/min |
| lR heater surface temperature | MAX450℃ PID control |
| hot wind temperature | MAX180℃ PID control |